Kestrel
®
4500 Pocket Weather
®
Tracker 25
et pour faire déler les diérents réglages. Utilisez les touches
et
stored once the log is full, in order to preserve it until it can be reviewed later. Be sure to clear the data
log just before your ight.
Skydiving
Auto Store On
Store Rate 2 sec
Overwrite O
Man Store O
These settings will allow you to record a detailed account of your jump. Be sure to clear the data log just
before jumping. As you descend toward the ground, you will be tracking the altitude every two seconds,
as well as the conditions at that altitude. The chart will clearly show the point at which the parachute
opens, as well as the point you get back on the ground.
HVAC - Environmental Monitoring
Auto Store On
Store Rate 5 min
Overwrite On
Man Store O
These settings will record conditions every ve minutes, for a total storage of almost 2 days. You can
monitor the conditions in a laboratory or manufacturing plant, both day and night, to determine if the
climate control is working properly. Or you can examine the eect on the environment when employees
enter and exit the building.
HVAC/R - System Balancing
Auto Store O
Store Rate —
Overwrite O
Man Store On
These settings will require you to press the Manual Store Button in order to store any data at a duct,
hood, vent, or other air system. The meter will not store any data automatically. Be sure to record the
location and date/time of storage for reference when reviewing the data. After storing the conditions at
each location, simply review the data and balance the system.
MEMORY CAPABILITIES
Store Rate Total Memory
2 sec 46 min, 40 sec
5 sec 1 hr, 56 min, 40 sec
10 sec 3 hr, 53 min, 20 sec
20 sec 7 hr, 46 min, 40 sec
30 sec 11 hr, 40 min
1 min 23 hr, 20 min
2 min 1 day, 22 hr, 40 min
5 min 4 days, 20 hr, 40 min
10 min 9 days, 17 hr, 20 min
20 min 19 days, 10 hr, 40 min
30 min 29 days, 4 hr
1 hr 58 days, 8 hr
2 hr 116 days, 16 hr
5 hr 291 days, 16 hr
12 hr 700 days